The inlet and outlet of the runner dehumidifier shall not be blocked by obstacles, and the air filter network shall be cleaned.

How to maintain the rotary wheel dehumidifier

1. The inlet and outlet of the runner dehumidifier shall not be blocked by obstacles, and the air filter network shall be cleaned.

2. The runner dehumidifier should be placed in the center of the room.

3. The condenser should be cleaned frequently and kept clean.

4. If the humidity in the air is below 30%, it is too dry and uncomfortable, so the reliable humidity controller is controlled to maintain the range of 50% ~ 60%. When using doors and Windows as close as possible, so that indoor dehumidification effect. The body should be placed flat, not inclined or horizontal, to avoid machine failure or abnormal sound.

5. When the surrounding temperature is lower than 15 ° C, the water droplets attached to the surface of the evaporator will freeze and weaken the dehumidifier effect. If the surrounding temperature exceeds 40 ° C, the pressure in the system will increase and the compressor will be overloaded. Therefore, the optimal temperature range of dehumidifier is 15 ° C to 40 ° C.

6, the wheel dehumidifier water storage is too full, in order to avoid the overflow of dirty wetland surface, and must be carried in the operation of the body, please unplug the power cord plug, and then pour the water in the water storage bucket.

7. The runner dehumidifier cleans the air filter network regularly (about once every two weeks) to maintain the dehumidification, dust removal efficiency and service life of the machine. Wash the filter network with water below 40℃; Use detergent to clean better, wash off the dust, rinse with water, dry after the body. When cleaning the body, gently wipe with a damp cloth; Avoid direct water cleaning, so as not to damage electrical insulation. Body surface has adhesive, can be cleaned with soapy water, to avoid gasoline, petroleum essence, solvent or spray type insecticide spray, in order to avoid the occurrence of peeling paint or discoloration phenomenon. Do not use thin rod, wire to dig inside the machine, in order to avoid failure or danger.

8. The runner dehumidifier should be moved for four to six hours before starting. Because the compressor pipeline in the dehumidifier contains cold coal, after moving, the cold coal must be returned to its original position after four to six hours.

9. In case of power failure or long-term use or travel, please unplug the power cord to maintain the life of the machine.